3. Connect the White wire from the Decagon Sensor to the terminal marked PWR as
shown above.
Wiring the AquaCheck soil moisture probe
Wiring the AquaCheck probe: Only 1 probe can be connected to this unit at a time.
1. Connect the Blue wire from the AquaCheck probe to the terminal marked SOIL as shown
above.
2. Connect the Yellow/Green stripe wire from the AquaCheck probe to any terminal marked
GND as shown above.
3. Connect the Brown wire from the AquaCheck probe to any terminal marked 5V OUT as
shown above.
to the Crop Link Unit