Maintronic DASPip UP Manuale rapido - Pagina 3

Sfoglia online o scarica il pdf Manuale rapido per Controllore Maintronic DASPip UP. Maintronic DASPip UP 6. Power pwm actuator 1ch

Connection to dimmer with PWM input
3. Connections
Screw terminal for 0.2 ... 2.5 mm² stranded wire
or 0.2 ... 4 mm² single wire
DASPip INS
N - Neutral conductor
N - Neutral conductor
L - Mains 230V AC
L´ - Load output (switched phase L´)
D1 - DALI data (alt. tastDIM)
D2 - DALI data (alt. tastDIM)
DIMM PWM + (brown wire)
DIMM PWM - (blue wire)
DASP
iP
INS
tc
DALI 1CH
POWER PWM
ACTUATOR
L
N
120-240 V
tast
DIM
ta 0-50C°
DALI
N
N
L L´
D1 D2
-X1
1 2 3 4
5 6
7
8
7
DASPip UP
1
N - Neutral conductor
2
N - Neutral conductor
3
L - Mains 230V AC
4
L - Mains 230V AC
5
L - Mains 230V AC
6
L´ - Load output (switched phase L´)
7
D1 - DALI data (alt. tastDIM)
8
D2 - DALI data (alt. tastDIM)
9
DIMM PWM -
10
DIMM PWM +
8
4. DALI general
DALI (Digital Addressable Lighting Interface) is a standardized
digital communication interface in the field of building auto-
mation.
4.1 DALI note
The DALI signal is not SELV (safety extra-low voltage), the ins-
tallation instructions for mains voltage apply.
The maximum cable length of the DALI control cable must not
exceed 300m (with 1.5mm² cable cross-section) or 2V voltage
drop.
4.2 Groups and Scenes
In each DALI circle 16 groups can be formed, with each 16
scenes. A scene includes the brightness value of a short
address.
4.3 DALI device-specific
The device search assigns a DALI short address to the DASPip
INS. Please note the operating instructions for your DALI con-
troller or gateway.
The module works accordingly to the following regulations:
IEC 62386-101, General requirements; System
IEC 62386-102, General requirements; Control gear
IEC 62386-207, Particular requirements for control gear -
LED-modules (device type 6)
9