Sfoglia online o scarica il pdf Istruzioni per l'installazione per Accessori per caminetti Majestic fireplaces 20010751. Majestic fireplaces 20010751 4. Fuel conversion kit lp to natural/natural to lp for model dv360

4. Converting LP to NG, remove bracket/gasket as-
sembly by unfastening the screw which secures the
bracket to the burner tray base. Discard bracket and
refasten the screw into the hole. (Fig. 9)
Converting NG to LP, assemble the bracket/gas-
ket assembly to the burner tray assembly base by
unfastening the screw on the tray to the right side of
the orifice. Slide the bracket/gasket assembly over
the fitting on the manifold toward the back with the
gasket to the right. Secure the bracket/gasket as-
sembly using the screw removed earlier. (Fig. 9)
Fig. 9 LP bracket/gasket assembly.
5. Replace the orifices according to the table on Page
�����
4.
�� �������
6. Replace the mixing tube on the burner housing by
removing the two (2) screws that secure the mixing
����
tube to the burner housing assembly. Remove the
old gasket behind the mixing tube. (Fig. 10) NOTE:
The mixing tube for propane gas has only two
bimetallic springs that are in the closed position
at cold start. The mixing tube for natural gas has
two spring/shutter collar assemblies that are in
the closed position at cold start. Make sure the
correct mixing tube is used for conversion.
7. Use the new gasket supplied in the conversion kit
and proper mixing tube and replace in reverse order.
8. Reassemble the burner housing assembly, the
burner tube assembly and the fettle in reverse orde
Pilot Orifice Conversion - R Models
NOTE: It is not necessary to remove the pilot tube for
conversion.
1. Remove pilot hood by lifting up. (Fig. 11)
2. Remove pilot orifice with Allen wrench. (Fig. 12)
3. Install conversion pilot orifice.
4. Re-install pilot hood and be sure to align with index
tab. Installation is complete.
LP Bracket/Gas-
ket Assembly - in
Fig. 10 Replace mixing tube and gasket.
place for use with
LP Gas; remove
for use with Natu-
ral Gas
Screw
CO132
Fig. 11 Remove pilot hood.
Fig. 12 Remove pilot orifice.
Pilot Orifice Conversion - RF Models
NOTE: It is not necessary to remove the pilot tube for
1. Loosen pilot hood turning counterclockwise using a
2. Remove pilot orifice with needlenose pliers. (Fig. 14)
3. Install conversion pilot orifice.
4. Reinstall pilot hood. Be sure to align pilot hood with
5. Turn the gas supply valve and gas valve on and test
6. Follow procedure on rating plate to light the pilot.
Gasket
Mixing Tube
Natural
Pilot Hood
Pilot
Bracket
Index Tab
Snap Ring
conversion.
CO106a
DV360/580
Gas Conversion
7/16" wrench. (Fig. 13)
Pilot2
1/28/00 djt
index marks.
for leaks. Use a 50/50 solution of liquid soap and
water to test for leaks at gas fittings and joints. Apply
water/soap solution with brush only - do not over ap-
ply. NEVER test with an open flame.
Check for leaks.
Burner Housing
Propane
CO131
�����
������ ����
���� ���
CO105a
Allen Wrench
CO105a
DV360/580
Gas Conversion
Pilot
1/28/00 djt
CO106a
3