DecoRad HandMate UV600 Manuale d'uso - Pagina 15
Sfoglia online o scarica il pdf Manuale d'uso per Attrezzature per l'edilizia DecoRad HandMate UV600. DecoRad HandMate UV600 17. Ultimate tool for instantly curing uv (floor) coatings
Anche per DecoRad HandMate UV600: Manuale rapido (2 pagine)
5. Error messages, shown on the display
Error
Description
E14 (TEMP)
Over-temperature
E15 (FAN)
Fan fail
E16 (SHUT)
Shutter error
E17
Temperature sensor
U51 (DIST)
Distance
U94 (TIME)
Time management
Solution
The UV lamp is too hot, leave the UV lamp 5 minutes to cool down. Turn
off the Handmate.
Follow the start procedure.
Please consult DecoRad® Systems in case of recurrence.
Leave the UV lamp 5 minutes to cool down, turn off the Handmate.
Follow the start procedure.
Please consult DecoRad® Systems in case of recurrence.
Leave the UV lamp to cool down, turn off the Handmate.
Follow the start procedure.
Please consult DecoRad® Systems in case of recurrence.
Leave the UV lamp to cool down, turn off the Handmate.
Follow the start procedure.
Please consult DecoRad® Systems in case of recurrence.
Please position the Handmate between 2 – 4 cm distance from the floor
UV curing is only possible at this distance.
Auto OFF after 5 minutes no use
Handmate UV 600 v. 2.4
15