Gardena 4000/5 Manuale di istruzioni per l'uso - Pagina 5

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Pompa dell'acqua Gardena 4000/5. Gardena 4000/5 17. Garden pump
Anche per Gardena 4000/5: Manuale di istruzioni per l'uso (10 pagine), Manuale di istruzioni per l'uso (12 pagine), Manuale dell'operatore (14 pagine), Manuale dell'operatore (11 pagine), Manuale dell'operatore (10 pagine), Manuale di istruzioni per l'uso (18 pagine), Manuale dell'operatore (10 pagine), Manuale di istruzioni per l'uso (19 pagine), Manuale di istruzioni per l'uso (13 pagine), Manuale di istruzioni per l'uso (17 pagine)

Gardena 4000/5 Manuale di istruzioni per l'uso

4. Using the Equipment for the First Time

Position of equipment:
Install automatic domestic
water system permanently:
©
Connect the hose to the
suction side:
Art. 1723 /
©
Art. 1724
©
The point at which the unit is fixed must be sound, dry and well
ventilated and must permit the pump to be set up in a stable
position.
➔ Install the pump at a safe distance (min. 2 m) from the pump-
ing medium.
The pump must be installed in a location with low air humidity
and sufficient ventilation in the area of the ventilation slots. It
must be at a distance of at least 5 cm from the walls. No dirt
contamination (e.g. sand or earth) may be sucked in through the
ventilation slots.
The mounting plate prevents the pump moving.
1. Screw mounting plate
2. Place pump on the base with both feet
Set the pump such that a suitably large container can be positioned
below the drain screw for emptying the pump or unit
If possible, install the pump higher than the surface of the water to
be pumped. If this is not possible, install a vacuum-resistant shut-
©
off device between the pump and the suction hose, for example
for cleaning the integrated filter.
If you install your Electronic Pressure Pump permanently indoors to
supply water for domestic use, connect your pump to the pipe
network using flexible hoses rather than rigid pipes. This will help
reduce noise and prevent damage to the manometric switch
©
due to vibration.
If the system is being installed permanently, please fit suitable
shut-off devices on both the intake and delivery sides. This is
important e.g. for maintenance and cleaning work or if the system
is being shut down.
The connection pieces on the intake and delivery sides must
only be tightened by hand.
Do not use any water hose snap connection system components
on the intake side. A vacuum-tight suction hose must be used e.g.
• GARDENA Suction Hose art. 1411
• GARDENA borehole Suction Hose art. 1729.
To reduce the pump repriming time, we recommend:
• using a suction hose with backflow preventer, which prevents
the suction hose emptying automatically when the Pressure
Tank Unit is switched off
• If the suction heights are high, use a suction hose with a small
diameter.
1. Connect vacuum-tight suction hose
(e.g. art. 1723 / 1724)
and screw in place so that it is airtight.
2. For suction heights exceeding 4 m also secure the suction
hose
(e.g. by fastening it to a wooden post).
This relieves the pump of the weight of the suction hose.
If very fine dirt is present, we recommend the use of a
GARDENA pump preliminary filter art. 1730 / 1731 in addition
to the integrated filter.
on to an appropriate base.
.
via a connection piece
to the connection on the intake side
.
17