alkitronic EFCip Manuale di funzionamento e manutenzione - Pagina 7
Sfoglia online o scarica il pdf Manuale di funzionamento e manutenzione per Hardware del computer alkitronic EFCip. alkitronic EFCip 16. Electric torque multiplier
4.4 Bolting programs
4.4.1 Bolting according to the torque method
Adjustment mode 1 - with/without automatic release function
Start Display
Enter
bolting program
Step 1
Enter
final torque
Step 2
Enter
release angle
Step 3
Correction procedere:
push button and
return to step 1.
"OK" signalisation (bolting pro-
cess was flawless, final torque is
reached).
"nOK" signalisation flashes (faulty
bolting).
electric torque multipliers
Once the values have been checked -
start bolting process.
Check settings, repeat bolting.
Take into account relevant provisions of bolting.
Use e.g. new bolts etc.
7
After a short time, the display
jumps to the next image.
Confirm input
Confirm input
Confirm input
No automatic release function:
Set angle to zero "0".
Confirm resp. the acknowledgment is automatically.
Place on next bolt/nut and start
bolting process.