2N Lift8 Manuale breve - Pagina 9

Sfoglia online o scarica il pdf Manuale breve per Sistema interfonico 2N Lift8. 2N Lift8 14. Io module
Anche per 2N Lift8: Manuale breve (8 pagine), Manuale breve (12 pagine), Manuale breve (13 pagine), Manuale breve (6 pagine), Manuale breve (12 pagine), Manuale breve (17 pagine)

2N Lift8 Manuale breve
Warning
Maintain the connection polarity to make the 2N
Safety
The bus is electrically isolated from the telephone line circuits according to the
EN60950 requirements and its low voltage cannot cause any electrical
accident.
Mode switch
Set the camera module connection mode with a 10-position switch 0–9:
0 - the camera module works within the 2N
CU/splitter via a 2-wire bus);
1 - the camera module works autonomously (see below for details);
2-9 - no setting (the red ERR LED is flashing).
IP camera connection
Connect the camera to the IP CAM Ethernet connector. The integrated DHCP server will
set IP address 10.0.0.1 to the camera.
Interconnect the IP camera with the camera module using an Ethernet cable.
Warning
Interconnect the camera module only with the IP camera only via the Ethernet
cable. No other connection is supported.
RS-232/RS-485 Camera Connection
Connect the camera to the SERIAL CAM connector using a push-on terminal board.
See the table below for connector details.
+5V
+UCC
Use the 2N® Lift8 Service Tool application to set the camera type and other
parameters.
TX/D
data transmitted
data received
®
Lift8 system work correctly.
®
Lift8 system (connected to the
RX/D+
GND
signal ground
8