Output Relay Connection
Every I/O Module is equipped with 4 bistable relays with the maximum load of 250 V / 5 A
per contact. Never exceed this limit to avoid system damage. When the relay is closed,
the respective LED signals this state. You can configure the relay function in
®
the 2N
Service Tool application.
Warning
Never exceed the voltage and current limits specified in the Technical
Parameters for the load applied to the relay contacts to avoid system damage.
Warning
Never connect any important structural devices such as brakes, door locks,
security equipment, etc. to the relay outputs. The I/O Module is not
designed and must not be used for such installations. Connect only the
devices that will not be damaged by unexpected relay contact disconnection
(CU remote upgrade, bus restart, etc.) such as unimportant signalling lamps,
ventilators, shaft lights, etc.).
The manufacturer shall not be held liable for damage incurred as a
result of improper installations on the relay contact.