Notes
Note the following issues when connecting the ETERNUS DX/AF to a server.
3.1

LAN Environment Notes

The ETERNUS DX/AF can be connected to a server via an existing LAN. However, a decrease in LAN perform-
ance may be observed by prior users of said LAN.
For the iSCSI LAN (used to transfer data), do not set multipath configuration with IP Network Multipathing
(IPMP).
Since an iSCSI LAN handles large amounts of data (traffic volumes) like an FC-SAN, the iSCSI LAN must have
its own switch and be a dedicated LAN that is separate from the business LANs.
For IP network security, separate the iSCSI LAN from the management LAN (for administration).
The iSCSI LAN must be configured as a dedicated LAN for each path from a server to the ETERNUS DX/AF.
A configuration where multiple LAN ports of a single server are connected to the same network may be
restricted depending on the OS and/or driver specifications. For a multipath connection, connect each path
using different LAN segments by separating the VLAN and so on.
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (iSCSI) for Oracle Solaris
9
Copyright 2017 FUJITSU LIMITED
P3AM-4042-18ENZ0