AQTRONIC SF53 Manuale operativo - Pagina 4
Sfoglia online o scarica il pdf Manuale operativo per Controllore AQTRONIC SF53. AQTRONIC SF53 5.
SF53
CNC PLASMA Torch Height Controller
"HYS" (Hysteresis see image 15 page 5) - The hystere-
sis voltage - a range in which the voltage is measured,
in which there are signals controlling UP/DOWN is
deactive.1-15V.Factory setting "1"
"dLy" (delay) - delay time of output OK when the sys-
tem detects the main (cutting) arc
1 - 15 seconds. factory setting: 1s
"CAL" (Calibration) - Due to material deviation the
recorded plasma voltage may need adjustment.
According to an external reference, such as the simple
voltmeter, you can modify the Plasma voltage reading.
-35V to +35V.Factory 0V
"LCU" (Low Voltage cut) - value of the off load voltage
detection in the plasma cutter - used to detect the
main (cutting) arc.Minus the preset value any control
outputs are disable.0-99V.Factory 40V
"HCU" (High Voltage cut) - value of the off load voltage
detection in the plasma cutter - used to detect the
main (cutting) arc.Over the preset value any control
outputs are disable.200-350V.Factory 350V
"tSt" (Test) - Simulation of the controller's work - the
system simulates the appearance of "floating" Torch
within a countdown timer.By pressing any keys you
can exit from test mode or just wait a few seconds for
auto exit.
"ESC" (Escape) - by pressing the up/down keys you
can exit of menu or just wait a few seconds for auto
exit.
4