Aqua Guard MasterPro Series Manuale d'uso - Pagina 6
Sfoglia online o scarica il pdf Manuale d'uso per Filtro per piscina Aqua Guard MasterPro Series. Aqua Guard MasterPro Series 12. Pool cartridge filter
Cartridge Cleaning
NOTICE: The pressure gauge is the primary indicator
of filter performance. Maintain the pressure gauge in
good working order. If the gauge is damaged, replace it
immediately.
When to clean the filter
The filter cartridge should normally be removed and cleaned
when the pressure gauge reads 8 - 10 PSI above the start-up
pressure noted below:
Installation date:
Start-up pressure:
Cleaning pressure:
In some pools/spas, accessories such as fountains, waterfalls,
and pool cleaners may be noticeably affected by the normal
decrease in flow as the filter becomes dirty. If so, these
systems may require more frequent cleaning (that is, at a
pressure increase of less than 10 PSI) to operate properly.
NOTICE: When using PHMB (polyhexamethylene
biguanide) based sanitizers, such as Baquacil®, special
care must be taken when cleaning the cartridge.
Cartridges in systems using these sanitizers must be
cleaned more frequently and thoroughly than chlorine
systems. PHMB based sanitizers also require the use
of special PHMB cleaners. Carefully follow the PHMB
sanitizer/cleaner manufacturer's instructions when
cleaning the filter. Use of any other type of cleansers with
PHMB sanitizers will permanently clog the filter and will
void the filter warranty
NOTICE: Failure to remove all oils and cleaning solution
before soaking cartridge in acid will permanently damage
the filter cartridge.
aquaguardpoolsystems.com
6
If the filter has a coating of algae, calcium carbonate (residue
from calcium hypochlorite), iron or other minerals, soak the
cartridge in a solution of one part muriatic acid to twenty
parts water (6 fl oz per gallon of water) until all bubbling
stops.
WARNING: Wear rubber gloves, protective
clothing and safety goggles when using acid.
Do not add water to acid, as splashing of full
strength acid could result.
Thoroughly rinse the cartridge to remove all acid
solution.
WARNING: When this procedure no longer
adequately cleans the cartridge, discard the cartridge and
replace it with a new one.
Carefully follow the steps in the "Filter Re-Assembly" section
of this manual.