Aqua Guard MasterPro Series Manuale d'uso - Pagina 7

Sfoglia online o scarica il pdf Manuale d'uso per Filtro per piscina Aqua Guard MasterPro Series. Aqua Guard MasterPro Series 12. Pool cartridge filter

FIGURE 5
Tighten clamp bolt
and nut using a
torque wrench to
150 inch-lbs.
Clamp Nut
Clamp Bolt

Filter Re-Assembly

WARNING: This product
should be installed and
serviced only by a qualified
pool professional.
Re-Installing Cartridges
1. Flush and drain any dirt or debris from the bottom of the
lower filter body.
2. Flush any dirt or debris from the upper body and from
around the manual air relief area.
3. Carefully replace the cartridges over the hubs on the
bottom seal plate.
4. Place top manifold securely on top of cartridges, aligning
the return pipe with the port in the manifold.
Clean Seal Ring and Seal Surface
1. Remove filter tank seal
2. With a clean cloth, wipe the lower filter body seal surface
and clean seal of all dirt and debris.
3. With a clean cloth wipe the upper filter
NOTICE: Do not use any petroleum solvents to clean filter
components. Do not lubricate seal.
Body and Clamp Re-Assembly
1. Place the metal reinforced seal on lower filter body. (See
Figure 7) Place upper filter body on metal reinforced
seal and lower filter body in a position which allows all
operation and safety labels to be clearly visible and the
upper filter body to be centered on the lower filter body.
Press down firmly and evenly on the upper filter body to
seat the seal. (See Figure 7)
2. Replace the filter clamp around the upper and lower filter
bodies. Hold the clamp ends to position the clamp on the
filter bodies with the clamp ends adjacent to the safety
and operation labels on the filter bodies. (See Figure 7)
3. Insert clamp bolt through the clamp ends and thread the
clamp nut onto clamp bolt with rounded end of the nut
(See Figure 6) towards the ends of the clamp.
FIGURE 6
Clamp Nut
Rounded end of nut
FIGURE 7
Align
Labels
Drain
Plug
Lower
Filter
Body
4. Never rely on hand tightening of clamp nut to clamp bolt.
Using a ¾" socket on a torque wrench, torque clamp nut
to clamp bolt to 150 inch-lbs. (See Figure 5)
WARNING: DO NOT HIT OR STRIKE CLAMP WITH HAMMER
OR METAL TOOLS.
5. Start the pump. See startup instructions on page 5.
Vacuuming Pool
Vacuuming can be performed directly into the filter
whenever needed. Clean cartridges after vacuuming, if
required.
Removing the Manual air relief valve
Your Filter comes with a Manual Air Relief Valve (MAR)
preinstalled from the factory.
For Qualified pool professionals only: If MAR valve needs to
be serviced, follow these instructions carefully.
1. Turn off all system circulation pumps and all electric
power on the equipment pad.
2. Set all system valves in a position to prevent water from
flowing to the filter.
3. The manual air relief valve must be placed in the OPEN
position. (See Figure 8)
4. Wait until all water leakage has stopped.
5. The air relief valve can be removed by screwing the whole
parts counter clockwise.
Re-Installation Of The Manual Air Relief Valve
1. Check the O-Ring seals, replace as needed.
2. With a clean cloth, wipe upper filter body and O-Ring
groove. Remove all dirt and debris
3. Align the notch in the MAR Flange
4. Press the MAR straight down into the upper filter body.
5. Turn the MAR clockwise until the indicator is aligned with
the LOCK position on the upper filter body.
6. Verify the MAR discharge points away from all electrical
connections.
FIGURE 8
To Open
To Open
AquaGuard | MasterPro
7