3.6 Grey Screen Appears
Description: When grey screen appears, it returns to normal temporarily after power off and reboot,
but then happens repeatedly.
Possible reason: Caused by insufficient power supply.
Solution: Check whether the IPC power supply is correct, or the power adapter is too far from the
IPC.
3.7 HD or SD IR Dome Camera has IR Image Reflection
or Haze in the Image
Solution: Put the IR-blocking ring on the lens or adjust the light-blocking ring to a proper position.