DFRobot Veyron Manuale - Pagina 6
Sfoglia online o scarica il pdf Manuale per Controllore DFRobot Veyron. DFRobot Veyron 14. Veyron servo driver 24-channel
Relationship between Steering Angle and PWM Signal
Formula
Run Time (sec) = pulse width (us) / Speed (us / sec).
e.g.The initial position is 750us, the finial position is 2250us, the speed is 1000us/s The running
time;
T=(2250-750)/1000=1.5s
So the running time is 1.5s.
Tutorial
Device List:
Veyron Servo Driver 24‐Channel
Micro USB cable
TowerPro SG90 Servo