Dell 3250 Manuale del prodotto - Pagina 32

Sfoglia online o scarica il pdf Manuale del prodotto per Computer portatile Dell 3250. Dell 3250 37. Product guide (.pdf)
Anche per Dell 3250: Aggiornamento delle informazioni (32 pagine), Manuale d'uso (39 pagine), Manuale d'uso (39 pagine), Manuale di avvio rapido (2 pagine)

Dell 3250 Manuale del prodotto
Beep Codes

10.1 Recovery Beep Codes

These audible codes describe the progress of a BIOS recovery attempt from a recovery CD
refer to chapter 11 Clearing CMOS and BIOS recovery for detail and steps to perform this
process.
Beeps
1 short
2 short
Repeating

10.2 BMC Beep Code Generation

The BMC generates beep codes upon detection of the failure conditions, each digit in the code
is represented by a sequence of beeps whose count is equal to the digit.
Code
1-5-1-1
FRB3 failure (processor failure)
1-5-2-1
Processor: Empty Slot
1-5-2-2
Processor: No Processors
1-5-2-3
Processor: Configuration Error (e.g., VID mismatch)
1-5-4-2
Power fault: DC power unexpectedly lost (power
control failures)
1-5-4-3
Chipset control failure
1-5-4-4
Power control fault
26

Table 8. Recovery Mode Beep Codes

Medium tone BIOS Flash Update Started
Medium tone BIOS Flash Update Complete
Low tone BIOS Recovery Error Occurred, or no recovery media found

Table 9. BMC Beep Codes

Reason for Beep
Intel® Server Platform SR870BH2
Description
Course of action
See "FRB" in Debug Methodology and failure
Isolation section.
No processor found in socket 1, See "Processor" in
Debug Methodology and failure Isolation section.
No processor found in socket 1, See "Processor" in
Debug Methodology and failure Isolation section.
General Processor Issue, See "Processor" in
Debug Methodology and failure Isolation section.
DC Voltage error, (1) check TPS power supply (s)
for amber lights – replace if found (2) Check /
replace power cage.
DC Voltage error, or dead short (MOST Common
cause) i.e. DC to GND (1) check TPS power supply
(s) for amber lights – replace if found (2) Check
Flex Cable for damage (nick in housing) or poor
connection – reseat cable or replace, check all
board to board connections i.e. VHDM connectors
(Riser to main board) carefully look for Bent or
flattened pins at end of connector near fans (3)
Check / replace power cage.
Revision 1.1