Dell 3250 Manuel du produit - Page 32
Parcourez en ligne ou téléchargez le pdf Manuel du produit pour {nom_de_la_catégorie} Dell 3250. Dell 3250 37 pages. Product guide (.pdf)
Également pour Dell 3250 : Information Update (32 pages), Manuel du propriétaire (39 pages), Manuel du propriétaire (39 pages), Manuel de démarrage rapide (2 pages)
Beep Codes
10.1 Recovery Beep Codes
These audible codes describe the progress of a BIOS recovery attempt from a recovery CD
refer to chapter 11 Clearing CMOS and BIOS recovery for detail and steps to perform this
process.
Beeps
1 short
2 short
Repeating
10.2 BMC Beep Code Generation
The BMC generates beep codes upon detection of the failure conditions, each digit in the code
is represented by a sequence of beeps whose count is equal to the digit.
Code
1-5-1-1
FRB3 failure (processor failure)
1-5-2-1
Processor: Empty Slot
1-5-2-2
Processor: No Processors
1-5-2-3
Processor: Configuration Error (e.g., VID mismatch)
1-5-4-2
Power fault: DC power unexpectedly lost (power
control failures)
1-5-4-3
Chipset control failure
1-5-4-4
Power control fault
26
Table 8. Recovery Mode Beep Codes
Medium tone BIOS Flash Update Started
Medium tone BIOS Flash Update Complete
Low tone BIOS Recovery Error Occurred, or no recovery media found
Table 9. BMC Beep Codes
Reason for Beep
Intel® Server Platform SR870BH2
Description
Course of action
See "FRB" in Debug Methodology and failure
Isolation section.
No processor found in socket 1, See "Processor" in
Debug Methodology and failure Isolation section.
No processor found in socket 1, See "Processor" in
Debug Methodology and failure Isolation section.
General Processor Issue, See "Processor" in
Debug Methodology and failure Isolation section.
DC Voltage error, (1) check TPS power supply (s)
for amber lights – replace if found (2) Check /
replace power cage.
DC Voltage error, or dead short (MOST Common
cause) i.e. DC to GND (1) check TPS power supply
(s) for amber lights – replace if found (2) Check
Flex Cable for damage (nick in housing) or poor
connection – reseat cable or replace, check all
board to board connections i.e. VHDM connectors
(Riser to main board) carefully look for Bent or
flattened pins at end of connector near fans (3)
Check / replace power cage.
Revision 1.1