Table 4. Other environmental requirements
Specification
Altitude, operating
Altitude, non-operating
Shock, operating
Shock, non-operating square shock
Shock, non-operating half sine shock
Vibration, operating
Vibration, non-operating, random chassis 0.47 G
Vibration, non-operating, random rack
Vibration, transporting
Acoustics
Power-on and reset
The firmware boot time from power-on reset or soft reset to SMP target readiness is typically less than two minutes. Actual
boot time may vary depending on your specific configuration.
Power supply unit
Table 5. AC Power supply unit specifications
Specification
Maximum output power
Voltage
Frequency
Holdup time
Inrush current
Leakage current
Efficiency
Power factor
34
Technical specifications
Measurement or description
900 meters @ 45°C ; 3050 meters @ 33°C
NOTE:
Ramp Altitude at 3.81m/s and temperature at 20˚C/Hr
Maximum 12,000 m (39,370 ft)
6.0 g, 11 ms. Four shocks positive and four negative in each of 3 axes, 24 total
shocks.
25g, 3ms. Three shocks positive and three negative in each of 3 axes, 18 total
shocks.
50g, 2ms. One time per face (except front and rear face), total 4 shocks.
0.21 G
5 Hz–500 Hz random; 10 minutes/axis
rms
; 4–5 00Hz; vertical axis; random; 90 minutes per axis
rms
0.39 G
; 4–500Hz; horizontal axis; random; 30 minutes per axis
rms
0.88 G
; 2–200Hz; random; minutes in normal shipping orientation
rms
1.15G
1 ~–200 Hz; 4 sides (bottom, top, left, right). 30 minutes per side based
rms
on ISTA 2A Standard
Operating sound power ≤ 8.0 Bels L
Measurement
800 W
● Low line 100-127 VAC
● High line 200-240 VAC
● 240 VDC (China only)
50/60 Hz
10 ms
55 A (maximum)
0.875 mA (maximum)
230 VRMS
● >90% @ 10% load
● >94% @ 20% load
● >96% @ 50% load
● >92% @ 100% load
115 Vac 50Hz/240 Vac 60 Hz
● >0.90 @ 5%-10% load
● >0.96 @ 20% load
● >0.98 @ 50% load
(@ 23 ± 2°C )
WAd