Dell PowerVault Series Manuale di recupero - Pagina 12

Sfoglia online o scarica il pdf Manuale di recupero per Immagazzinamento Dell PowerVault Series. Dell PowerVault Series 40. Data protection solution system

Figure 3-2. Rebuilding a RAID 5 disk group
If you had installed a global hot spare allocated to the same PERC adapter of
the failed disk, the RAID group will automatically switch the role of the failed
disk with the hot-spare disk, and begin the rebuild operation automatically. In
this case, you would need to replace the failed disk and assign it as the new
global hot spare for that PERC adapter. Refer to the "Assign and Unassign
Hot Spares" section of the OpenManage™ Server Administrator's User's Guide
for more information on global hot spares.
About RAID 5 Degraded Mode
When a failed hard drive is replaced, the RAID group begins an automatic
rebuild operation. During this operation, data and parity information is
reallocated across all hard drives in the RAID group. Until the rebuild
completes, performance of the RAID group is degraded. You should continue
to monitor the status of the rebuild to ensure it completes successfully.
NOTE:
If another hard drive fails while the RAID group is rebuilding, all data on that
RAID group may be lost.
12
Recovering From Disk Failures