Dell PowerVault Series 복구 매뉴얼 - 페이지 12
{카테고리_이름} Dell PowerVault Series에 대한 복구 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerVault Series 40 페이지. Data protection solution system
Figure 3-2. Rebuilding a RAID 5 disk group
If you had installed a global hot spare allocated to the same PERC adapter of
the failed disk, the RAID group will automatically switch the role of the failed
disk with the hot-spare disk, and begin the rebuild operation automatically. In
this case, you would need to replace the failed disk and assign it as the new
global hot spare for that PERC adapter. Refer to the "Assign and Unassign
Hot Spares" section of the OpenManage™ Server Administrator's User's Guide
for more information on global hot spares.
About RAID 5 Degraded Mode
When a failed hard drive is replaced, the RAID group begins an automatic
rebuild operation. During this operation, data and parity information is
reallocated across all hard drives in the RAID group. Until the rebuild
completes, performance of the RAID group is degraded. You should continue
to monitor the status of the rebuild to ensure it completes successfully.
NOTE:
If another hard drive fails while the RAID group is rebuilding, all data on that
RAID group may be lost.
12
Recovering From Disk Failures