Dell SC180 Manuale d'uso - Pagina 28

Sfoglia online o scarica il pdf Manuale d'uso per Immagazzinamento Dell SC180. Dell SC180 37. Storage center
Anche per Dell SC180: Manuale d'uso (39 pagine)

Dell SC180 Manuale d'uso

Identifying the Failed Enclosure Management Module

To determine which EMM failed, use the Dell Storage Client.
1.
Click the Hardware tab.
2.
In the Hardware tab navigation pane, select the Storage Center.
3.
In the Hardware Alerts area, find the hardware alert that identifies the enclosure with the failed EMM
(IO Module).
Figure 19. Hardware Alert Identifying the Enclosure with the Failed EMM
4.
In the Hardware tab navigation pane, expand the enclosure identified in the previous step.
5.
Select I/O Modules. The status of each EMM is displayed in the I/O Modules tab.
6.
Select the failed EMM to the display its location in the I/O Module View tab.
28
Replacing SC180 Components