Identifying the Failed Enclosure Management Module
To determine which EMM failed, use the Dell Storage Client.
1.
Click the Hardware tab.
2.
In the Hardware tab navigation pane, select the Storage Center.
3.
In the Hardware Alerts area, find the hardware alert that identifies the enclosure with the failed EMM
(IO Module).
Figure 19. Hardware Alert Identifying the Enclosure with the Failed EMM
4.
In the Hardware tab navigation pane, expand the enclosure identified in the previous step.
5.
Select I/O Modules. The status of each EMM is displayed in the I/O Modules tab.
6.
Select the failed EMM to the display its location in the I/O Module View tab.
28
Replacing SC180 Components