Dell PowerConnect M8428-k Manuale - Pagina 23
Sfoglia online o scarica il pdf Manuale per Interruttore Dell PowerConnect M8428-k. Dell PowerConnect M8428-k 25. Dell poweredge m710 and m710hd - system memory update
Anche per Dell PowerConnect M8428-k: Manuale di aggiornamento (32 pagine), Note di rilascio (27 pagine), Manuale d'uso (23 pagine), Manuale di aggiornamento (1 pagine)
After loading the .pfw file, both the software and firmware will be programmed onto the 10GbE
PTM.
The update process takes a few minutes.
Note:
At the end of this process, the following message will be displayed at the prompt:
# Received update image successfully. Changes will take effect after
next reboot.
#
Exit the 10GbE PTM CLI to the CMC command line. Run:
Step 6.
# exit
Power cycle the 10GbE PTM for the firmware to take effect. From the CMC command line type
Step 7.
the following command:
$ racadm chassisaction -m switch-<n> powercycle
Wait for 20 seconds, and then connect to the 10GbE PTM. Run:
Step 8.
$ connect switch-<n>
You will be able to view the progress of the SW update.
At the end of a successful SW update process, the following message will be displayed:
Step 9.
FW updated successfully!
Welcome to the Dell 10GbE PTM Management Console firmware X.X.XXX-<date
stamp>
#
Login to the 10GbE PTM CLI as admin. Run:
Step 10.
# login admin
To confirm that all PhyX® chips have the same firmware version, run the command:
Step 11.
& show image ver
Software image version: X.X.XXX-<date stamp>
Component #1 FW version: Y.Y.YYY
Component #2 FW version: Y.Y.YYY
Component #3 FW version: Y.Y.YYY
&
Rev 1.00
23