Dell PowerConnect M8428-k Manuel - Sayfa 23

Anahtar Dell PowerConnect M8428-k için çevrimiçi göz atın veya pdf Manuel indirin. Dell PowerConnect M8428-k 25 sayfaları. Dell poweredge m710 and m710hd - system memory update
Ayrıca Dell PowerConnect M8428-k için: Güncelleme Kılavuzu (32 sayfalar), Sürüm Notları (27 sayfalar), Kullanıcı Kılavuzu (23 sayfalar), Güncelleme Kılavuzu (1 sayfalar)

Dell PowerConnect M8428-k Manuel
After loading the .pfw file, both the software and firmware will be programmed onto the 10GbE
PTM.
The update process takes a few minutes.
Note:
At the end of this process, the following message will be displayed at the prompt:
# Received update image successfully. Changes will take effect after
next reboot.
#
Exit the 10GbE PTM CLI to the CMC command line. Run:
Step 6.
# exit
Power cycle the 10GbE PTM for the firmware to take effect. From the CMC command line type
Step 7.
the following command:
$ racadm chassisaction -m switch-<n> powercycle
Wait for 20 seconds, and then connect to the 10GbE PTM. Run:
Step 8.
$ connect switch-<n>
You will be able to view the progress of the SW update.
At the end of a successful SW update process, the following message will be displayed:
Step 9.
FW updated successfully!
Welcome to the Dell 10GbE PTM Management Console firmware X.X.XXX-<date
stamp>
#
Login to the 10GbE PTM CLI as admin. Run:
Step 10.
# login admin
To confirm that all PhyX® chips have the same firmware version, run the command:
Step 11.
& show image ver
Software image version: X.X.XXX-<date stamp>
Component #1 FW version: Y.Y.YYY
Component #2 FW version: Y.Y.YYY
Component #3 FW version: Y.Y.YYY
&
Rev 1.00
23