Entec EW-4200D Manuale di istruzioni per l'uso - Pagina 14

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Generatore portatile Entec EW-4200D. Entec EW-4200D 19. Marine diesel generators

Entec EW-4200D Manuale di istruzioni per l'uso
Operation

MANUAL HAND STARTING

Manual hand starting is similar, but not identical to, Starting the
Engine for the First Time.
1. Follow steps 1 through 8 in Starting the Engine for the First
Time.
2. Put the Off/Run/Start switch in the Run position.
3. Place the Handcrank in the Camshaft. Position your body to
the front of the unit. Grasp the handcrank in your left hand
and gently rotate it counterclockwise for two or three turns.
This action will pre-lube the bearings.
3. Now crank energetically to build up inertia in the moving
parts of the engine. Each time the handcrank makes one
revolution, the compression release will automatically index
one step. On the seventh turn the Compression Release will
reset itself to normal compression mode. Do not slow down.
Your body energy added to the inertia will help you pull
through the compression stroke and create ignition. When this
happens, the engine will start.
All three lights on the control panel should be illuminated and
will remain so until the engine is stopped by the operator, or
the safety system detects a problem (26/0).
NOTE: Do not be afraid of the Handcrank. It will not back-
fire. It will automatically disengage itself from the Camshaft.
We suggest you try the manual start method for the first time
when the engine is warm from running.
14
16710 SW 72nd • Portland, Oregon 97224 • (503) 624-7118
EW-4200D
Handcrank on
Camshaft
Control Panel
Entec West, Inc.