Miele G 1202 Manuale - Pagina 18

Sfoglia online o scarica il pdf Manuale per Lavastoviglie Miele G 1202. Miele G 1202 46.
Anche per Miele G 1202: Manuale (14 pagine)

Technical Information
Function
Resetting standard
settings
Adjusting the main wash
temperature
(ID nos. -984 and later)
Final rinse temperature
modification (ID nos. -984
and later)
Program running time
reduction
(ID nos. -984 and later)
Water quantity
normal/increased
(ID nos. -876 and later)
Soak activation/
deactivation
Pre-wash
activation/deactivation
Programming
Press the GEL button 12x.
The "GEL" LED flashes
once slowly and 2x quickly
intermittently. Press the
Program button to reset
all standard settings.
Press the GEL button 20x.
The "GEL" LED flashes 2x
slowly intermittently. Press
the Program button as
appropriate to make the
desired setting.
Press the GEL button 21x.
The "GEL" LED flashes 2x
slowly and once quickly
intermittently. Press the
Program button as
appropriate to make the
desired setting.
Press the GEL button 22x.
The "GEL" LED flashes 2x
slowly and 2x quickly
intermittently. Press the
Program button as
appropriate to make the
desired setting.
Press the GEL button 23x.
The "GEL" LED flashes 2x
slowly and 3x rapidly
intermittently. Press the
Program button as
appropriate to make the
desired setting.
Press the GEL button 24x.
The "GEL" LED flashes 2x
slowly and 4x quickly
intermittently. Press
Program to change the
setting.
Press the GEL button 25x.
The "GEL" LED flashes 2x
slowly and 5x quickly
intermittently. Press the
Program button as
appropriate to make the
desired setting.
18
G 1xxx/G 2xxx
Display
This programmable function can be
used to reset all customer-modified
parameters back to their standard
settings. The display shows P and a
digit alternately. P0 = Settings have
been modified; P1 = All settings
reset to standard settings or no
modifications have been made.
The display shows p and a digit
alternately. Setting options: p0 =
Standard setting; p1 = Wash
temperature increased. If this option
is selected, the main wash
temperature is increased and, as a
result, the program duration is
extended.
The display shows p and a digit
alternately. Setting options: p0 =
Standard setting; p1 = Wash
temperature increased. If this option
is selected, the final rinse
temperature is increased and, as a
result, the program duration is
extended.
The display shows p and a digit
alternately. Setting options: p0 =
Standard setting; p1 = Program
running time reduction.
Temperatures are decreased and/or
hold times removed, so the program
running time is shortened.
The display shows p and a digit
alternately: p0 = Normal water
quantity (standard setting); p1 =
Increased water quantity. If p1 is
selected, approx. 16.7 fl.oz.
(500mL) more water is taken in
during each water intake cycle.
The display shows p and a digit
alternately. Options: p0 = Soak not
activated; p1 = Soak activated.
The display shows p and a digit
alternately. Setting options: p0 =
Pre-wash not activated; p1 =
Pre-wash activated.