Miele DA 209 Manuale di istruzioni per l'uso - Pagina 14
Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Cappa di ventilazione Miele DA 209. Miele DA 209 36. Cooker
Operation
Filter operating hours counter
An indicator lamp shows when the
grease filter needs to be changed. The
operating hours counter for the grease
filters is set at the factory for a certain
number of hours but these can be
changed.
The operating hours counter for the ac-
tive charcoal filter is set at "unlimited",
as this is only relevant if using your
cooker hood in recirculation mode with
an active charcoal filter fitted. If you are
choosing to use recirculation mode the
hours counter for the active charcoal fil-
ter must be set for a specific time.
At the end of the set period the indica-
tor lamp for the grease filter touch con-
trol or the lamp for the active charcoal
filter touch control glows. The grease fil-
ter must then be cleaned. The active
charcoal filter needs to be replaced.
The filter operating hours counter must
then be re-set for the same period as
before.
Press the grease filter touch control
or the charcoal filter touch control for
about 4 seconds.
The indicator lamp will go out.
14
Reading the filter operating
hours counter
Before reaching the end of the period
set, you can check the percentage of
the time set which has already been
used up.
Use the On/Off touch control to
switch the fan on.
Press the grease filter touch control
or the active charcoal filter touch
control.
One or several of the indicator lamps
for the _ touch control will glow.
The number of flashing lamps show the
percentage of the operating time set
which has already been used up:
1 lamp = less than 25 %
2 lamps = less than 50 %
3 lamps = less than 75 %
4 lamps = less than 100 %
The operating hours completed remain
in memory, even when the machine is
switched off or there is a power cut.