Default Setting
Recommended Setting
b. Idle Timeout
Default Setting
Recommended Setting
This option sets the timeout value for Wake-On-ME.
The default timeout value is 65535 from the factory and it is in units of a
minute. A value of 0 means the Wake-On-ME feature is disabled and the
ME will not go to sleep when not being used in a non-active system. HP
recommends a setting of 65535 for most applications. . Certain console
vendor's product falsely detect an AMT system as disconnected if the
software has to wait for the ME to wake and respond. If the console
software being used does not have this issue, HP recommends a setting of
1 which allows the ME to go to sleep after approximately 1 minute of
inactivity. This allows for maximum power savings when the ME is enabled
to be on in S3, S4, or S5.
The timeout value can be set in decimal and hexadecimal notation. It must
be set to a non-zero value for the ME to take advantage of Wake-On-ME.
This value is not used when the system is in an active state – S0.
This value is used only if the ME ON in Host Sleep State setting is set to
allow ME WoL.
See Appendix C for an explanation of Wake-On-ME / ME WoL.
18) Go into AMT Configuration menu
Check the Manageability Feature Selection.
Default Setting
Recommended Setting
19) Check SOL/IDE-R under Intel AMT Configuration menu.
a. A message window telling the user that the system resets after configuration
will appear.
Select Y.
b. Username and Password
Default Setting
Recommended Setting
Select Enabled.
This option allows users and passwords to be added from the WebGUI. If
it is disabled, then only the administrator has MEBx remote access.
c. Serial Over LAN
Default Setting
Recommended Setting
Select Enabled.
: Desktop: ON in S0
: Desktop: ON is S0, ME Wake in S3, S4-5
: 65535
:65534
: Enabled
: Enabled
: Enabled
: Enabled
: Enabled
: Enabled