3B SCIENTIFIC PHYSICS Escola 10 Foglio di istruzioni - Pagina 3
Sfoglia online o scarica il pdf Foglio di istruzioni per Multimetro 3B SCIENTIFIC PHYSICS Escola 10. 3B SCIENTIFIC PHYSICS Escola 10 6.
Anche per 3B SCIENTIFIC PHYSICS Escola 10: Foglio di istruzioni (4 pagine)
Operating alignment:
Power supply:
Connectors:
Voltage ranges:
Current ranges:
Input resistance:
Voltage drop when
measuring current:
Accuracy:
Electrical
zero-point offset:
Accuracy with
zero-point offset:
Frequency ranges:
1 V – 600 V:
0.3 V:
Current ranges:
Signal form:
Peak factor:
Overload protection
Voltage:
Current ranges:
Current limit integral:
Transient limitI
:
FMS
Long-term current
limitI
:
FAV
Ambient temperature: 5° C...23°C...40° C
Storage temperature:
Relative humidity:
Shock tests:
Electrical safety:
Safety specifications:
Excess voltage
category:
Contamination level:
Protection type:
Electromagnetic compatibility:
Interference emission: EN 55011:2009
Interference resistance: EN 61326-1:2013
Vertical/horizontal
1x 1.5 V, AA IEC LR6
4-mm safety sockets
0.1, 0.3, 1, 3, 10, 30,
100, 300, 600 V AC/DC
0.1, 0.3, 1, 3, 10, 30,
100, 300 mA; 1, 3, 10 A
AC/DC
1 M AC/DC
100 mV approx. AC/DC
DC class 2, AC class 3
in all DC ranges
Class 5
20 Hz...50 Hz...20 kHz
20 Hz...50 Hz...9 kHz
20 Hz...50 Hz...43 kHz
Sine (1% max. discrep-
ancy)
2
600 V long-term in all
voltage ranges
2
450 A
s
300 A
20 A
-20...70° C
< 85% with no conden-
sation
max. 147 m/s²
EN 61010-1
CAT I: 600 V
2
IP20
4. Description
The Escola 10 multimeter enables precision
measurements by analogue means in education,
training and practical applications. It measures
AC and DC voltage or current and provides for
measurements with the needle centred on the
dial for DC quantities. Resistance (R) and con-
ductance (G) or impedance (Z) and admittance
(Y) can be obtained by division.
All measurement ranges are selected by means of
the measurement range dial. Two linearised mirror
scales, graded in a 1:3 ratio, guarantee easy read-
ability of the measured values.
The equipment is turned on by means of the
operating mode switch, which is also used to
select between AC, DC or centre zero-point.
The trimmer for setting the zero point in the
centre allows the zero point to be set precisely
when it drifts electrically.
Isolation of the sockets for voltage and current
measurement allow both to be measured in
succession simply by turning the range selector
switch, without any need for reconnecting or
changing the measuring leads.
Use of a robust core-magnet measuring instrument
set-up and an impact resistant casing allows the
instrument to withstand rough handling in awkward
conditions.
The Escola 10 is protected in such a way that
overloads in the selectable current ranges
automatically cause the power to be limited.
5. Operation
Switch the multimeter on by select the de-
•
sired operating mode,
To turn off the multimeter, set the mode
•
switch to the off position
To test the battery, disconnect all leads from
•
the multimeter, set the operating mode
switch to
switch to
needle should deflect all the way to the end.
If this is not the case, the battery must be
replaced immediately.
3
,
or
.
and the measuring range
. In the