aquatherm AT550 Manuale di installazione - Pagina 11
Sfoglia online o scarica il pdf Manuale di installazione per Pompa di calore aquatherm AT550. aquatherm AT550 14. Swimming pool & spa heat pumps w/titanium heat exchanger
E. ELECTRICAL CONNECTIONS AND WIRING
5. INTERFACING DIGITAL LOGIC CONTROL MODELS
with Aquaswitch or JI2000
• If you are using a Jandy AquaSwitch or JI2000 control run a 3 wire cable from the control to the
heater. Remove the 6 screws from the heaters front service access panel and open. Look for the
heater's solid state circuit board located inside the top portion of the electrical compartment mounted
on the rear wall. Locate the 3 terminals labeled POOL SPA SWITCH. Attach the 3 wire cable as
shown below. Do not remove any jumpers. Run the wire through the heater's low voltage access
port.
• Next, attach the 3 wire cable to the HEATER to the three terminal positions labeled POOL SPA
SWITCH
LEFT POSITION= LOW/POOL
CENTER POSITION= COMMON
RIGHT POSITION= HIGH/SPA
FAN
240 VAC
KEY PAD TERMINAL
POOL
DEF.
WATER
LOW
SENSOR
SENSOR
PRESS.
PRESS.
POOL
SWITCH TERMINALS
Attach the other end of the 3 wire cable
to the JI2000 as follows:
#10 For the HIGH/SPA
#11 For the LOW/POOL
#12 For the COMMON
Attach the other end of the 3 wire cable
to the AquaSwitch as follows:
#12 For the HIGH/SPA
#13 For the COMMON
#14 For the LOW/POOL
6. COMPOOL Cp3800, Cp3600 & Cp3400 Series Equipment
Heat pumps require a relay kit (Model RLY-LX) be added. The HTR connection used for gas
heaters cannot be used.
To wire a heat pump:
1. At the Power Center, install the relay into the high voltage compartment. Plug control wire
into the EHTR relay socket on the Power Center circuit board.
2. Run a 2-conductor cable from the heater to the Power Center,
3 At the heater, remove jumper and connect 2-conductor cable to the terminals.
4. At the Power Center, connect 2-conductor cable to LINE 1 and LOAD 1of the relay terminal
block.
5. Turn thermostat settings all the way up on the heat pump.
3 WIRE
TEST
T.C.O.
DEG. F
CABLE
JUMPERS
SEE
NOTE #4
HIGH
COMP.
T.C.O.
PRESS.
RELAY
OR
PR
WH
TN
HIGH/SPA
COMM.
LOW/POOL
10
#10 HIGH/SPA
#11 LOW/POOL
#12 COMMON
#12 HIGH/SPA
#13 COMMON
#14 LOW/POOL