Digiflex RF159 Manuale di riferimento per l'installatore - Pagina 3
Sfoglia online o scarica il pdf Manuale di riferimento per l'installatore per Controllore Digiflex RF159. Digiflex RF159 8. 2 channel smart rf controller - 433mhz
Receiver Operation
The RF159 will turn on the green RX LED to indicate the unit is powered and it will blink off each time a signal is re-
ceived. Each time a keyfob button is pressed the corresponding relay will operate and a confirmation signal is sent to
the keyfob to indicate a successful 2 way transaction. When button RLY1 or RLY2 are triggered manually they operate
the corresponding relay to allow you to test your connections and device your operating.
WARNING always be sure to check that there is no objects in the way when operating an automatic device as this
could cause damage or injury to a person.
Relay Programming
RLY1 and RLY2 can be individually programmed to operate in pulse or toggle mode by selecting the corresponding
mode number. Pulse mode is available in different timings from 1 second to 120 seconds to allow easy interface to
automatic gates and doors . Toggle mode will operate the relay when the keyfob button is pressed and will release
the relay on the next keyfob button press.
Action
Enter Relay
1
Programing Mode
2
Selecting The Relay
RLY1 LED will flash the number of times corresponding to the currently programmed setting.
3
Set Relay Mode
RLY1 LED will flash the number of times corresponding to the currently programmed setting, pause then repeat.
1=1s, 2=2s, 3=3s, 4=4s, 5=5s, 6=10s, 7=20s, 8=60s, 9=120s, 10=toggle
Program Other
4
Relay
RLY1 LED will flash the number of times corresponding to the currently programmed setting, pause then repeat.
1=1s, 2=2s, 3=3s, 4=4s, 5=5s, 6=10s, 7=20s, 8=60s, 9=120s, 10=toggle
Exit Programming
5
Mode
Copyright © 2020
Steps
Press RLY1 and RLY2 For 4
seconds
Press Relay Button To
Select (E.g. RLY1)
Press Relay Button To
Change Mode (E.g. RLY1)
Each time you press RLY1 it will increment to the next mode as follows.
Press Relay Button To
Select (E.g. RLY2)
Each time you press RLY1 it will increment to the next mode as follows.
Press RLY1 and RLY2 for 1
seconds or timeout
after 60 seconds
LED Legend
Table 1: RF159 Relay Programming
E&OE
Program Relay Functions
LED's
RF: ON
PGM: ON
RLY1: ON
RLY2: ON
RF: ON
PGM: ON
RLY1: Pulse current mode
RLY2: OFF
RF: ON
PGM: ON
RLY1: Pulse current mode
RLY2: OFF
RF: ON
PGM: ON
RLY1: OFF
RLY2: Pulse current mode
RF: On
PGM: OFF
RLY1: OFF
RLY2: OFF
Fast Flash
Slow Flash
Steady On
Steady
Red
Red
Red
Green
Comment
RLY1
PGM
RLY1
PGM
RLY1
PGM
RLY1
PGM
RLY1
PGM
OFF
P/N: RF159IRG Rev 1.3
RF
RLY2
RF
RLY2
RF
RLY2
RF
RLY2
RF
RLY2
Page