Press the right arrow key
values are shown:
Temperature / Pressure./ Air Speed
The ambient temperature reading can be shown in metric (°C) or imperial (°F) units. To
change the units of display, go to the main setup menu page by pressing the
(function "MEN"), select the "MAIN SETUP" menu and go (M-SET \ n. 24 U-TE).
Note: temperature sensor is inside the instrument and takes several minutes to reach
the external temperature. Differences in readings of about 1° or 2° are normal.
It is possible to adjust the temperature indication, go to (MAIN SETUP \ n. 25 KTMP).
4.5
PRESSURE DISPLAY
The pressure can be shown on the BASIC/ADVANCED DISPLAY screen.
To display the barometric pressure press the
To recalibrate the barometer, go to (M-SET \ n. 12 KBAR)
Attention: Incorrect re-calibration makes the readings of the barometer & the altimeters
less accurate.
4.6
AIR SPEED (WITH OPTIONAL AIR SPEED PROBE)
To display your air speed, you must have an air speed probe
connected. The optional air speed probe should be plugged in to
the right hand socket on the bottom of the vario.
The air speed reading can be shown in metric (km/h) or imperial (mph) units. To change
the units of display, go to (M-SET \ n. 23 U-SP) menu & then change to "MHP" or "KMH".
The airspeed can be shown on the BASIC/ADVANCED DISPLAY screen.
To display the air speed press the
4.6.1 STALL ALARM
To activate the stall alarm function, you must have an air speed probe connected. The
optional air speed probe should be plugged in to the right hand socket on the bottom of
the vario. It is possible to adjust the value that visual and acoustic the stall alarm is
activated. Go to (M-SET \ n. 9 STAL). Enter the value in km/h.
4.6.2 AIR SPEED RECALIBRATION
If the air speed probe is showing inaccurate readings, it is possible to recalibrate the air
speed probe, go to (M_SET \ n. 11 KIAS). An adjustment (in %) of the air speed reading
can be made, (100% = no adjustment, 110% = increase, 90% = decrease).
to switch between the functions. In sequence the following