Digilent DMC60C Manuale di riferimento - Pagina 14

Sfoglia online o scarica il pdf Manuale di riferimento per Controllore Digilent DMC60C. Digilent DMC60C 15.

Digilent DMC60C Manuale di riferimento
14 Restoring Factory Default Connections
Perform the following steps to restore factory default settings:
1. Disconnect the power source from the DMC60C.
2. Hold the Brake / CAL button down.
3. While continuing to hold the button, apply power to the DMC60C.
4. Continue holding down the button until the top and bottom LEDs alternate quickly between
Green and Off.
5. Release the Brake / CAL button.
The manufacture date string, hardware revision number string, and serial number string will be
retained. All other non-volatile configuration variables, including the CAN bus device number, are
reset to their factory default stat
                      https://reference.digilentinc.com/dmc‐60c/hardware‐reference‐manual/2‐4‐19