Cisco 9124 - mds multilayer fabric switch Nota di rilascio - Pagina 18

Sfoglia online o scarica il pdf Nota di rilascio per Interruttore Cisco 9124 - mds multilayer fabric switch. Cisco 9124 - mds multilayer fabric switch 44. Mds 9000 series
Anche per Cisco 9124 - mds multilayer fabric switch: Specifiche tecniche (2 pagine), Scheda tecnica (9 pagine), Specifiche tecniche (3 pagine), Manuale di configurazione (49 pagine), Nota di rilascio (48 pagine), Nota di rilascio (36 pagine), Nota di rilascio (22 pagine), Nota di rilascio (3 pagine), Nota di rilascio (40 pagine), Manuale (16 pagine), Manuale di installazione dell'hardware (36 pagine)

Cisco 9124 - mds multilayer fabric switch Nota di rilascio
Upgrading Your Cisco MDS SAN-OS Software Image
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Note
Check the syslogs for any ISL that was isolated.
Step 3
2005 Aug 31 21:52:04 switch %FCDOMAIN-2-EPORT_ISOLATED:
%$VSAN 2005%$ Isolation of interface
port-channel 52 (reason: unknown failure)
2005 Aug 31 21:52:04 switch %FCDOMAIN-2-EPORT_ISOLATED: %$VSAN 2005%$
Isolation of interface port-channel 51
(reason: domain ID assignment failure)
Issue the following commands for the isolated switches in Step 3:
Step 4
switch(config)# vsan database
switch(config-vsan-db)# vsan vsan-id suspend
switch(config-vsan-db)# no vsan vsan-id suspend
Step 5
Issue the ivr refresh command to perform an IVR refresh on all the IVR enabled switches.
Step 6
Issue the copy running-config startup-config command to save the RDI mode in the startup
configuration on all of the switches.
Step 7
Follow the normal upgrade guidelines for Release 2.1(2b). If you are adding new switches running Cisco
MDS SAN-OS Release 2.1(2b) or later, upgrade all of your existing switches to Cisco SAN-OS Release
2.1(2b) as described in this workaround. Then follow the normal upgrade guidelines for Release 3.3(3).
Note
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(3)
18
Complete Step 2 for all IVR enabled switches before moving to Step 3.
RDI mode should not be disabled for VSANs running in interop mode 2 or interop mode 3.
OL-14116-11