Activate a DC Power Supply
Use the information in the table below to estimate the power requirements and heat dissipation of a router is
based on a given configuration of the router. Determining power requirements is useful for planning the power
distribution system needed to support the router.
Activate a DC Power Supply
Perform the following procedure to activate a DC power supply:
SUMMARY STEPS
1. Remove the tape from the circuit-breaker router handle, and restore power by moving the circuit-breaker
router handle to the On (|) position.
2. Verify power supply operation by checking if the respective power supply front panel LED (PS0 or PS1)
is green.
3. If the LEDs indicate a power problem, see
4. If you are connecting a redundant DC power supply, repeat these steps for the second power source.
DETAILED STEPS
Step 1
Remove the tape from the circuit-breaker router handle, and restore power by moving the circuit-breaker router handle
to the On (|) position.
Step 2
Verify power supply operation by checking if the respective power supply front panel LED (PS0 or PS1) is green.
Step 3
If the LEDs indicate a power problem, see
Step 4
If you are connecting a redundant DC power supply, repeat these steps for the second power source.
If you are connecting a redundant DC power supply, ensure that each power supply is connected to a separate
Note
power source in order to prevent power loss in the event of a power failure.
Activate an AC Power Supply
Perform the following procedure to activate an AC power supply:
SUMMARY STEPS
1. Plug the power cord into the power supply.
2. Connect the other end of the power cord to an AC-input power source.
3. Verify power supply operation by checking if the respective power supply front panel LED (PS0 or PS1)
is green.
4. If the LEDs indicate a power problem, see
5. If you are connecting a redundant AC power supply, repeat these steps for the second power source.