DIGISYSTEM APS20201 Manuale di istruzioni - Pagina 5

Sfoglia online o scarica il pdf Manuale di istruzioni per Alimentazione DIGISYSTEM APS20201. DIGISYSTEM APS20201 9. Variable frequency vibrators power supply

DIGISYSTEM APS20201 Manuale di istruzioni
PIN REF.
SIGNAL DESCRIPTION
PC1
GROUND CONNECTION
M3-6
PC1
MAINS INPUT (NEUTRAL)
M3-5
PC1
MAINS INPUT (PHASE)
M3-4
GROUND CONNECTION
D2-T
OUTPU SUPPLY FOR VIBRATOR
D2-1
D2-2
OUTPU SUPPLY FOR VIBRATOR
PC3
0V INSULATED
M2-4
PC3
START COMMAND INPUT
M2-3
(required current 10 mA)
PC3
+18V INSULATED
M2-1
PC3
OUTPUT INVERTER OK SIGNAL
(PNP)
M2-2
Note:
The guts of the vibrator must be grounded with a appropriate wire.
Before feeding the device verify that there are not ground dispersions on
wires connecting the power supply to the vibrator; The power supply will be
damaged if one of the two output wires is grounded.

WIRING TABLE

WIRE
SECTION
mmq
3x1
3x1
3x1
3x1
shielded
3x1
shielded
3x1
shielded
5
WIRE
COLOR
YELLOW-GREEN
BLUE or
WHITE
BROWN
CONNECT TO:
EARTH
230 Vac
230 Vac
VIBRATOR
MECHANICAL
VIBRATOR COIL
VIBRATOR COIL
0V
SENSOR OR
CONTACT
+18V
PLC INPUT