Sfoglia online o scarica il pdf Istruzioni per il montaggio e il funzionamento per Apparecchiature industriali Siemens SIMOGEAR 2730. Siemens SIMOGEAR 2730 48. Geared motor with rotary encoder for safety-relevant applications

The responsibility and liability regarding functional safety and its associated traceability is
completely transferred to the operating company:
• If the operating company damages the seal that was attached by Siemens.
• If the operating company carries out work in the area around the seal.
• If the operating company performs work on the rotary encoder or the brake and the
respective mechanical connection.
4.2

Unpacking

NOTICE
Transport damage impairs the correct functioning of the geared motor.
Never commission a damaged geared motor.
Check the geared motor for completeness and for damage. Report any missing parts or
damage immediately.
Keep the connector protection cap of the encoder on the connector until you connect the
encoder to a suitable encoder evaluation unit.
Remove and dispose of the packaging material and transport equipment in compliance with
regulations.
SIMOGEAR functionally safe rotary encoder
Operating Instructions, 01/2024, A5E53220857A/RS-AA
Ensuring functional safety
4.2 Unpacking
27