Siemens SIMOGEAR 2730 Istruzioni per il montaggio e il funzionamento - Pagina 30

Sfoglia online o scarica il pdf Istruzioni per il montaggio e il funzionamento per Apparecchiature industriali Siemens SIMOGEAR 2730. Siemens SIMOGEAR 2730 48. Geared motor with rotary encoder for safety-relevant applications

Ensuring functional safety
4.3 Electrical installation of the encoder
Position of the encoder below the cover
2480 Encoder
2605 Fan cover of the motor/external fan
2615 Canopy
2648 Encoder cover
4.3

Electrical installation of the encoder

Non-qualified personnel
If the encoder is electrically installed by inadequately qualified personnel then the functional
safety can be disabled.
Only fully qualified personnel may carry out work on a functionally safe rotary encoder.
These persons must be knowledgeable about:
• Topics relating to functional safety
• Legislation, safety regulations and standards for functional safety
• Content of the detailed operating instructions provided
28
Self-ventilated motor
Motor with forced ventilation
Motor with forced ventilation and brake
WARNING
SIMOGEAR functionally safe rotary encoder
Operating Instructions, 01/2024, A5E53220857A/RS-AA