5.2.6

Installing the load cell with pendulum support

Death or serious bodily injury
A falling load bearing implement can lead to considerable material damage, serious injury
or death, depending on the potential risk.
NOTICE
Damaging of load cells
Incorrect or incomplete installation can result in damage to the load cells, installed parts
and the load bearing implement.
Observe the warning notices at the start of the chapter, see: Safety information/instructions
(Page 19).
Plane of the mounting surfaces
A plane of ≤ 0.2 mm is required for the mounting surfaces.
Compressive strength of the mounting surfaces
The compressive strength of the mounting surfaces has to be appropriate for the surface
pressure of the load cell mounting rings.
RN-S SA
Operating Instructions, 09/2013, A5E32962759A-01
WARNING
5.2 Mounting the pressure piece set
Installation
25