Argo AWICS19 Manuale di istruzioni per l'installazione - Pagina 14

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Condizionatore d'aria Argo AWICS19. Argo AWICS19 18. Split air conditioner system

14 - MATCH BETWEEN REMOTE CONTROLLER AND INDOOR UNIT

EN
(TRANSMISSION CHANNEL)
The remote control can be addressed to use up to 4 different units installed in the same room.
You can get unified control by using a single remote control for all units or each remote control can be addressed to its
own unit, in order to control separately temperature, timer and all other functions.
PCB SETTING
• Disconnect the unit power supply and wait at least 60 seconds, making sure that all the lamps go off.
• Remove the front panel to access the pcb.
• Set SW3 as shown in the table.
• Close the front panel.
• Reconnect the unit power supply.
REMOTE CONTROLLER SETTING
• Press the button
• Press the arrow
• Press the button
number 0 (factory setting) at the bottom starts flashing.
• Press the arrow
• Confirm with the button
• Press
to exit the menu.
CHANNEL
0
FACTORY STATE
1
2
3
for a few seconds.
until you visualize 06.
again for a few seconds: the
to set 0, 1, 2 or 3.
.
REMOTE CONTROL UNIT
WIRED CONTROLLER SETTING
• Press the MENU / PARAMETERS button for 2 seconds.
• Use the  /  buttons until 6 is displayed.
• Press the OK button for 2 seconds: now it is possible
to change the value of the parameter using the  / 
buttons.
• Set 0, 1, 2 o 3.
.
Press OK to confirm
SW3: 1=OFF 2=OFF
SW3: 1=ON 2=OFF
SW3: 1=OFF 2=ON
SW3: 1=ON 2=ON
14
UNIT PCB