Argo POLIFEMO CLASS Manuale di istruzioni per l'uso - Pagina 4

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Condizionatore d'aria Argo POLIFEMO CLASS. Argo POLIFEMO CLASS 6. Evaporative air cooler
Anche per Argo POLIFEMO CLASS: Manuale di istruzioni per l'uso (11 pagine)

Argo POLIFEMO CLASS Manuale di istruzioni per l'uso
The appliance does not need to be installed.
Position the unit on a flat, stable surface and connect the power cord to a suitable power socket (230 V~): you will hear a
sound to indicate that the appliance is in standby and can be switched on using the START/SPEED button. The unit can
be switched off using the OFF button.
This product can be used either as a fan, with 3 modes (Normal, Natural and Sleep) and 3 fan speed options (low,
medium and high), or as a cooler/humidifier: in this case the rear tank should be filled with
not exceeding the maximum level as indicated. When the water in the tank falls below the minimum level (marked on the
tank), the appliance emits a continuous sound for 10" to signal a low water level, then cooling mode is stopped. The unit
automatically shuts down when the tank is removed.
The fan takes in air from the room and passes it through the dust filter and the evaporative panel, which is constantly
humidified thanks to a system which draws water from the tank and sprays it onto the panel. The incoming hot air makes
part of the water contained in the panel evaporate and is therefore cooler when released back into the room, which makes
it feel as though the temperature has dropped.
START/SPEED button
In standby mode, press this button to start the
appliance, which in 3" will reach its lowest fan
speed level (1); the corresponding LED will
light up. The appliance is set by default to run
in "Normal" mode. Press this button again to
change the fan speed.
1 (low)- 2 (medium) - 3 (high)
COOLER/HUMIDIFIER button
(COOLING/HUMIDIFICATION)
Press this button to activate the "Cooler/Humidifier" mode: the LED
lights up. The fan speed will automatically change to low (1). 5
minutes later, the fan mode and fan speed selected before this mode
was activated will be restored: at this point it will be possible to
change the mode and fan speed set previously, using the MODE
and START/SPEED buttons respectively.
MODE button
Press this button once to switch from "Normal" mode, activated by default when the START/SPEED button is pressed, to "Natural" mode
.
Press the button a second time to move to "Sleep" mode
corresponding LEDs light up accordingly.
In each of the 3 modes, it will then be possible to select the desired speed: High (3), Medium (2) or Low (1).
The "Natural" mode has 3 fan levels (1, 2, 3), each with different periods in which the high, medium and low speeds alternate, in order to
create a very natural type of ventilation.
An example of this is illustrated on the graph below.
H
M
Level 3 (high)
L
stop
H
Level 2 (medium)
M
L
stop
H
M
Level 1 (low)
L
stop
The "Sleep" mode has 3 fan levels (1, 2, 3), each with different periods in which the high, medium and low speeds alternate in Natural
mode, in order to create a very natural type of ventilation at night.
Sleep mode - Level 3 (high) : 30' in Natural mode level 3 + 30' in Natural mode level 2; then continues in Natural mode level 1.
Sleep mode - Level 2 (medium) : 30' in Natural mode level 2, then continues in Natural mode level 1.
Sleep mode - Level 1 (low) : Natural mode level 1 only.
V 01/12

HOW TO USE THE APPLIANCE

CONTROL PANEL and AVAILABLE FUNCTIONS
FAN MODE SELECTION (Natural, Sleep)
5S
5S
5S
3S
10S
5S
5S
5S
5S
5S
5S
3S
10S
5S
10S
5S
3S

TIMER button

Press this button to start the operating timer for a period
of time between 0.5 and 7.5 hours: every time the button
is pressed, the time will increase by half an hour. It is
deactivated by continuing to press it until the time
disappears.
OFF button
Press this button to exit all
functions and enter standby
mode.
. Press a third time to exit the fan mode selection procedure: the
10S
5S
5S
3S
5S
10S
10S
10S
3S
5S
10S
5S
5S
3S
5S
demineralized
SWING button
(ROTATION)
Press this button to activate
rotation of the round air delivery
grille. Press this button again to
stop rotation. The corresponding
LED lights up and switches off
accordingly.
5S
5S
T=76S
10S
3S
T=74S
minutes
5S
5S
3S
T=74S
water, up to but
10