Fimer PVS-10-TL-SY SPD1+2 Manuale di installazione rapida - Pagina 8
Sfoglia online o scarica il pdf Manuale di installazione rapida per Inverter Fimer PVS-10-TL-SY SPD1+2. Fimer PVS-10-TL-SY SPD1+2 8. Solar inverter

11. Features and Technical Data
Input side
Absolute maximum DC input voltage (Vmax,abs)
Start-up DC input voltage (Vstart)
Operating DC input voltage range (Vdcmin...Vdcmax)
Rated DC input voltage (Vdcr)
Rated DC input power (Pdcr)
Number of independent MPPT
Recommended maximum PV array power (PPV, max)
Maximum DC input power for each MPPT (PMPPT,max)
MPPT DC voltage range (VMPPTmin ... VMPPTmax) at Pacr
Maximum DC input current (Idcmax) for each MPPT
Maximum input short circuit current for each MPPT
Maximum return current (AC side vs DC side)
Number of DC inputs pairs for each MPPT
DC connection type
Type of PV panels that can be connected according to IEC 61730
Input protection
Reverse polarity protection
Input over voltage protection for each MPPT
Photovoltaic array isolation control
Residual current monitoring Unit (leakage current protection)
DC switch rating for each MPPT (version with DC switch)
String Fuse
Input current monitoring
Output side
AC Grid connection type
Earthing system
Rated AC power (Pacr @cosf=1 )
Maximum AC output power (Pacmax @cosf=1)
Maximum apparent power (Smax)
Maximum reactive power (Qmax)
Nominal power factor and adjustable range
Rated AC grid voltage (Vac,r)
Maximum AC output current (Iac,max)
Contributory fault current
Rated output frequency (fr)
Output frequency range (fmin...fmax)
Max DC Current Injection (% of Iac,max)
Maximum AC cable
AC connection type
Output protection
Anti-islanding Protection
Maximum external AC overcurrent protection
Output overvoltage protection
Operating performance
Maximum Efficiency (ηmax)
Weighted Efficiency (EURO)
Environmental
Operating ambient temperature range
Storage temperature
Relative Humidity
Sound pressure level, typical
Maximum operating altitude
Environmental pollution degree classification for external environments
Environmental class
Physical
Inverter typology
Environmental Protection Rating
Cooling System
Dimension (H x W x D)
Weight
Overvoltage rating as per IEC 62109-1
Safety
Safety class
Insulation Level
Marking
1. The AC voltage range may vary depending on specific country grid standards.
2. The Frequency range may vary depending on specific country grid standards.
3. Please refer to the document "String inverters – Product manual appendix" available at
fimer.com
for information on the quick-fit connector brand and model used in the inverter.
4. Hereby, FIMER S.p.A. declares that the radio equipments (radio module combined with
Features not specifically mentioned in this data sheet are not included in the product.
For more information
please contact your
local FIMER
representative or visit:
fimer.com
FIMER_PVS-10_12.5_15-TL_Quick Installation Guide_EN_RevA
We reserve the right to make technical changes or
modify the contents of this document without prior notice.
With regard to purchase orders, the agreed particulars
shall prevail. FIMER does not accept any responsibility
whatsoever for potential errors or possible lack of
information in this document.
PVS-10-TL
10200 W
14500 Wp
7800W
17A
Negligible in normal operating conditions
Yes, according to IEC 62109-2 or according to local regulation
Rating DC-PV1. 50A@600Vdc, 40A@800Vdc, 30A@1000Vdc
10000 W
10000 W
10000 VA
6000 VAR
16 A
25 A
98.4%
98.1%
-25...+60°C (-13...140 °F) with derating above 45 °C (113 °F)
40 dB(A) @ 1m
4000 m (13123 ft) with output power [Pout ] linear derating
Grid connected, Double stage, Transformerless
H = 568.2 mm / 22.37" (644mm / 25.35" with AC quick fit connector) ; W =
the inverter) are in compliance with the Directive 2014/53/EU. The full text of the EU
Declaration of Conformity is available at the following internet address:
www.
5. @ 4000m (45° C ambient temperature), the output power (Pout) is reduced by 15%.
6. In the event of a fault, limited by the external protection envisaged on the AC circuit.
We reserve all rights in this document and in the
subject matter and illustrations contained therein. Any
reproduction, disclosure to third parties or utilization of
its contents – in whole or in parts – is forbidden without
prior written consent of FIMER. Copyright© 2021 FIMER.
All rights reserved.
PVS-12.5-TL
PVS-15-TL
1100 V
250...500V (default 360V)
200...1000 V
620V
12760 W
15300 W
2
18125 Wp
21750 Wp
8300W
10000W
460-850V
18A
22A
30 A
2
PV quick fit connector
(3)
Class A
Yes, from current limited source
SPD Type 2 / Type 1+2 (optional)
Yes, according to IEC 62109-2
Fuseless
String level
Three phase (3W+PE or 4W+PE)
TN-S, TN-C, TN-CS, TT
12500 W
15000 W
12500 W
15000 W
12500 VA
15000 VA
7500 VAR
9000 VAR
> 0.995; 0...1 inductive / capacitive
380V, 400V
(1)
20 A
23 A
Iac,max x 1,15
50 Hz / 60 Hz
47...53 Hz / 57...63 Hz
(2)
< 0.5%*Iac,max
16 mm
copper
2
AC quick fit connector
According to local standard
32 A
32 A
SPD Type 2
98.5%
98.5%
98.2%
98.2%
-40°C...+85°C / -40°F...185°F
4...100 % with condensation
45 dB(A) @ 1m
45 dB(A) @ 1m
above 2000m (6561 ft)
(5)
3
Outdoor
IP65
Natural
473.6 mm / 18,64" ;
D = 207 mm / 8,15"
29.6 Kg / 65lb
II (DC input) III (AC output)
I
Transformerless
CE
,RCM
(4)
(6)
www.fimer.com
22-03-2021
8