Cisco ONS 15454 SDH E1-75 Manuale di riferimento rapido - Pagina 14

Sfoglia online o scarica il pdf Manuale di riferimento rapido per Server Cisco ONS 15454 SDH E1-75. Cisco ONS 15454 SDH E1-75 16. Impedance conversion panel
Anche per Cisco ONS 15454 SDH E1-75: Manuale (40 pagine), Manuale di riferimento (22 pagine), Installazione (13 pagine)

Cisco ONS 15454 SDH E1-75 Manuale di riferimento rapido
Table 1
DWDM (continued)
RTRV-TRC-OCH:[<TID>]:<SRC>:<CTAG>::[<MSGTYPE>],[<TRCLEVEL>][::];
Retrieves the sent trace string, expected trace string, received trace string, trace mode, and trace level
for the SONET J0 Section Trail Trace Identifier (TTI) Path and Section monitoring levels of the
DWDM facility.
Output format:
SID DATE TIME
M CTAG COMPLD
"<CHANNEL>,<MOD>::[TRCLEVEL=<TRCLEVEL>,][EXPTRC=<EXPTRC>,][TRC=<TRC>,]
[INCTRC=<INCTRC>,][TRCMODE=<TRCMODE>,][TRCFORMAT=<TRCFORMAT>]"
;
RTRV-WDMANS:[<TID>]:<AID>:<CTAG>{::::};
Retrieves the automatic optical node setup application attributes.
Output format:
SID DATE TIME
M CTAG COMPLD
"<AID>::[POWER-IN=<POWERIN>,][POWEROUT=<POWEROUT>,]
[POWER-EXP=<POWEREXP>,][NTWTYPE=<RINGTYPE>,]
[OPTICALTYPE=<OPTICALTYPE>,][LASTRUNDAT=<LASTRUNDATE>,]
[LASTRUNTM=<LASTRUNTM>][:]"
;
RTRV-WLEN:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the wavelength provisioning information.
Output format:
SID DATE TIME
M CTAG COMPLD
"<AID>:<WCT>:[SIZE=<SIZE>]:[<PST>],[<SST>]"
;
SCHED-PMREPT-<MOD2>:[<TID>]:<SRC>: <CTAG>::[<REPTINVL>],[<REPTSTATM>],
[<NUMREPT>],,[<MONLEV>],[<LOCN>],,[<TMPER>],[<TMOFST>];
Schedules/reschedules the NE to report the performance monitoring data for an OMS facility, using
an automatic REPT^PM message. It also allow the user to remove a previously created schedule.
SET-ALMTH-<MOD2>:[<TID>]:<AID>:<CTAG>::<CONDTYPE>,<THLEV>[,,,];
Sets the alarm thresholds on a facility/port/channel.
SET-TH-<MOD2>:[<TID>]:<AID>:<CTAG>::<MONTYPE>,<THLEV>,[<LOCN>],,[<TMPER>];
Sets the thresholds for PM and the alarm thresholds for a card facility.
14