Epson ProofPlus TM-H6000III Manuale di sviluppo - Pagina 31

Sfoglia online o scarica il pdf Manuale di sviluppo per Scanner Epson ProofPlus TM-H6000III. Epson ProofPlus TM-H6000III 32. Ecc printer
Anche per Epson ProofPlus TM-H6000III: Manuale del prodotto (27 pagine), Opuscolo (2 pagine), Specifiche tecniche (2 pagine), Opuscolo (6 pagine), Manuale d'uso (32 pagine), Manuale di sviluppo (26 pagine), Manuale di sviluppo (45 pagine), Manuale (10 pagine), Manuale d'uso (29 pagine)

Epson ProofPlus TM-H6000III Manuale di sviluppo
Upon completion of EndInsertion
The data format
is illegal
method, the following retune values
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_CHECKDIGIT
A part of the
Upon completion of EndInsertion
data
is
not
method, the following retune values
analyzable
are set:
Or
RC: OPOS_SUCCESS
Noise error is
RCE: 0
occurred
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_BADDATA
Upon completion of EndInsertion
The
cover
is
opened
during
method, the following retune values
insertion
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_COVEROPEN
Upon completion of EndInsertion
The
paper
is
method, the following retune values
jammed
during
insertion
are set:
RC: OPOS_SUCCESS
RCE: 0
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_EXTENDED
RCE: OPOS_EMICR_JAM
27
APPLICATION DEVELOPMENT GUIDE
MICR (EPSON TM Series)
Version 3.00 Feb. 2019
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_SUCCESS
RCE: 0
When "Fire ErrorEvent on check
digit parity error" check box in
"Device Specific Setting" dialog is
marked , the result of data analysis
is notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_ILLEGAL
RCE: OPOS_EMICR_DIGITERROR
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_E_ILLEGAL
RCE: OPOS_EMICR_BADDATA
The result of data analysis is
notified by ErrorEvent.
RC and RCE of the ErrorEvent are as
follows:
RC: OPOS_E_ILLEGAL
RCE: OPOS_EMICR_DATAERROR
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_E_OFFLINE
RCE: 0
There is no notification by event.
Upon completion of EndInsertion
method, the following retune values
are set:
RC: OPOS_E_OFFLINE
RCE: 0
There is no notification by event.