b) KEY-IN jack - amplifier input for receive/transmit control from the transceiver.
The transceiver switches the amplifier from receive mode into transmit mode (RX/TX) by grounding of
the KEY-IN input.
Run a shielded cable from the output of your transceiver, providing "ground on transmit", to the KEY-IN
input on the amplifier rear panel (RCA PHONO jack – Fig. 2-1). Use a standard RCA PHONO plug for
connection to the amplifier.
Transceiver manufacturers give different names to this output, for example: TX-GND, SEND, T/R LINE,
RELAY, and others. In some transceivers "ground on transmit" output should be activated by a menu
or via changing a switch on the rear panel or inside the transceiver. See instructions in your transceiver
manual.
c) KEY-OUT jack - transmit-enabling control output from amplifier to the transceiver.
The KEY-OUT jack on the rear panel provides an extra control signal from the amplifier to the transceiver.
This can be used for improving the receive/transmit (RX/TX) switching safety.
If your transceiver has a suitable input, that disables transmission unless grounded externally, we
recommend this to be connected to the KEY-OUT jack of the amplifier. Use shielded cable terminated
with а standard RCA PHONO plug.
Voltage on the KEY-IN jack does not exceed 12V and the current
is below 6mA. See also S. 8-2(a).
Your amplifier will not work if the KEY-IN input is not connected
correctly. If you experience any difficulty consult your dealer.
Fig. 2-1 Rear panel connections
KEY-OUT is a low-powered open-collector output, make sure
that the signal voltage coming from the respective transceiver
connection does not exceed 50VDC (open circuit) and the closed-
circuit current is below 20mA.