Whirlpool DryAire LMA1053L Manuale - Pagina 19

Sfoglia online o scarica il pdf Manuale per Asciugatrice Whirlpool DryAire LMA1053L. Whirlpool DryAire LMA1053L 32. Drying cabinet
Anche per Whirlpool DryAire LMA1053L: Manuale (32 pagine)

Whirlpool DryAire LMA1053L Manuale
REMOVING THE BLOWER ASSEMBLY,
THE THERMOSTAT & TEMPERATURE SENSOR
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
NOTE: Sharp edges may be present.
1.
Disconnect the power to the drying cabi-
net.
2.
Remove the component panel (see page
4-2 for the procedure).
3.
To remove the blower assembly:
a) Disconnect the wires from the fan mo-
tor terminals.
b) Remove the four screws from the
blower assembly and remove it.
Blower Assembly
2 Screws
4.
To remove the thermostat and tem-
perature sensor:
a) Remove the two mounting screws and
lockwasher from the shield and remove
the shield from the component panel
(see the photo in step 3 on the previ-
ous page).
2 Screws
Fan Motor Wires
b) Remove the knob from the thermostat
control shaft.
c) Remove the two screws and lock-
washers from the thermostat.
d) Disconnect the wires from the thermo-
stat terminals.
e) Slide the sensor tube out of the slotted
rubber grommet, and then pull the end
of the sensor from the other rubber
grommet.
Temperature
Sensor
Sensor Tube In
Slotted Grommet
4-5
Thermostat Knob
Thermostat Screws/
Lockwashers
Thermostat
Wires