Whirlpool 36" (91.4 cm) WALL-MOUNT CANOPY RANGE HOOD Istruzioni per l'installazione e manuale d'uso e manutenzione - Pagina 9

Sfoglia online o scarica il pdf Istruzioni per l'installazione e manuale d'uso e manutenzione per Cappa di ventilazione Whirlpool 36" (91.4 cm) WALL-MOUNT CANOPY RANGE HOOD. Whirlpool 36" (91.4 cm) WALL-MOUNT CANOPY RANGE HOOD 28. 36" (91.4 cm) wall-mount canopy range hood

WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
8. Use twist-on connectors and connect green or bare wire with
yellow-green wire.
9. Replace terminal box cover.
10. Check all light bulbs to make sure they are secure in their
sockets.
11. Reconnect power.

Complete Installation

1. Check lights and blower operation. See "Use and Care Guide"
section.
If hood does not operate:
■ Check that the circuit breaker is not tripped or house fuse
blown.
■ Disconnect power. Check that wiring is correct.
2. For non-vented (recirculating) installations, install the charcoal
filter. See "Use and Care Guide" section.
3. Place the 2 L-brackets onto the glass hood.
A
4. Slide the glass hood on the blower housing.
5. Attach M4x35 screws to secure the glass hood.
A
6. Install vent cover by placing both vent covers on the hood.
7. Secure lower vent cover to hood with 2 screws, one on
either side.
8. Lift upper vent cover to the ceiling.
A. L-bracket
A. Screws
9. Secure upper vent cover to vent cover bracket with 2 screws,
one on either side.
A
A. Vent cover bracket
B. Upper vent cover
C. Lower vent cover
B
C
9