EXTRACTOR OR FILTERING HOOD INSTALLATION
The minimum distance between the support surface of the recipients on the cooking device and the lowest part of
the hood must not be less than 60 cm in case of electric cookers and 70 cm for gas or combination cookers. If the
installation instructions for the gas cooker specify a greater distance, this must be taken into account. Contact a
qualified technician for installation.
Do not connect the hood to the electrical power supply until installation is completed.
Warning! The exhaust pipe and clamps are not supplied and must be bought separately.
Very heavy product; hood handling and installation must be carried out by at least two persons.
Before beginning installation, decide which version of the hood you wish to use:
Extractor Version: fumes are extracted and expelled to the outside through an exhaust duct fixed to the collar (B) at the top
of the hood.
Warning! If the hood is has a carbon filter fitted, the filter must be removed.
Filter Version: air is filtered through two carbon filters and recycled into the surrounding environment.
Warning! If the hood is not equipped with carbon filters, they must be ordered and fitted before use.
1. Mark a centre-line on the wall from the cooktop to the ceiling.
2. Bearing in mind the minimum heights over the cooktop specified above, mark the height of the hood on the wall with a
pencil and place the template against the wall on the mark.
3. Using the template supplied, mark the holes, drill them and insert the rawlplugs, partly tighten 1 screw in the top rawlplug.
4. Fix the flue support to the wall as close as possible to the ceiling.
5. Hook the hood.
6. Adjust the position.
7. Fully tighten the top fixing screw.
8. Remove the grease filters and fix the hood from inside using 2 screws and washers.
9. depending on hood version:
Extractor Version:
Fix an exhaust duct with the right diameter to the exhaust outlet of the hood and connect to an exhaust system ducted to the
outside (for fixture and connection of exhaust duct, utilize the most suitable system for the duct purchased).
Filter Version
Install the filter connection F on the collar B and secure with 1 screw.
• Connect the hood to the power supply!
Telescopic flue installation:
10. Fix the telescopic flue tot he support with two screws.
11. Slide the bottom section down into its seat on the top of the hood.
5019 300 01026