4. Repeat steps 1-3 for the underside of the top of the cabinet.
i i'
I'
c ti
Cabinet
cm)
*From watt, not cabinet frame
Wall Venting
To make a 31/2 '' x 101/2 '' (8.9 cm x 26.7 cm) rectangle in the
wall:
1. Make 2 lines by measuring 3/8"(0.9 cm) and 37/8"(9.8 cm)
down from underside of cabinet and mark on the centerline
on the back wall.
2. Mark lines 51¼"(13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
51/4"
5V4"
(13.3 cm)
(13.3 cm)
Style 2 - Cut Openings for 31/4'' x 10" (8.3 x 25.4 cm)
Rectangular
Vent to Round Vent Transition
Roof Venting
To make a 41/4'' x 101/2 '' (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet bottom:
1. Mark lines 1/2"(1.3 cm) and 43/4"(12.1 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 51¼'' (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
12.1 cm)
/
5V4"
\
(13.3 cm)
*From watt, not cabinet
frame
To make a circular vent opening on the underside of the
cabinet top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line 5" (12.7 cm) from the back wall on the underside
of the top of cabinet.
3. Use a compass or a circle template to draw a circle with a
diameter that is 1¼,, ( 0.64 cm) larger than the vent.
4. Use saber or keyhole saw to cut the circular vent opening.
Circutar
vent opening
//'
/i
*From wall, not
cabinet
frame
J
Cabinet
cutouts
Style 3 - Cut Openings for 7" (17.8 cm) Round Vent
To make a circular vent openings on the underside of the
cabinet top and bottom:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line 5" (12.7 cm) from the back wall on the underside
of the top and bottom of cabinet.
3. Use a compass or a circle template to draw a circle with a
diameter that is 1¼,, ( 0.64 cm) larger than the vent.
4. Use saber or keyhole saw to cut the circular vent opening.
1 7V4" (18.4 cm) diam.
cabinet
cutouts
*From wail
not
cabinet
frame
Install Vent System
1. Install vent through the vent opening in upper cabinet or wall.
Complete venting system according to the selected venting
method. See "Venting Requirements"
section.
2. Use caulking to seal exterior wall or roof opening around the
cap.