Sfoglia online o scarica il pdf Manuale di funzionamento, manutenzione e installazione per Sistema di sicurezza Alderon Industries 7001 Versa’larm. Alderon Industries 7001 Versa’larm 3. Tank alarm
UniMax ™
Operation, Matintenance
and Installation Manual
Warning: Turn off all power when installing or adjusting unit.
Failure to turn off all power could result in serious injury or death!
Read instructions thoroughly.
Check local codes and install to meet requirements.
Note: Check to make sure the right float switch is being used fot the right application.
Normally Open - float switches are open while hanging "down" and will close on a ris-
ing liquid level. Typically used for high level alarms and "empty tank" applications.
Normally Closed - float switches are closed while hanging "down" and will open on a
rising liquid level. Typically used for low level alarms and "filling tank" applications.
Stainless Steel Pipe Clamp Models
1. Determine desired activation level. See Figure 1.
2. Attach the Stainless Steel Pipe Clamp at the desired activation Level. Place the cord in the plastic holder
and tether cord to about 4 inches and tighten screw tight to keep the cord from moving.
3. Connect the wires from the float switch into control/alarm device as required.
4. Check installation by cycling the float "on & off" to insure proper operation.
Externally Weighted Models
1. Determine desired activation level. See Figure 2.
2. Suspend switch and cable weight at desired level. See Figure 4.
3. Wire leads of the float switch to control/alarm device as required.
4. Check installation by cycling the float "on & off" to insure proper operation.
Pipe Clamp Models
Figure 1
Activation
Level
Unimax
Control
Float
Big Switch
Pump Float
Typical application shown is for a
pumping system
Specifications
Electrical: 1 amp @ 24 VDC or 4 amps @ 120/230 VAC
Cord: SJOW-A flexible 16 gauge, 2 conductor Neoprene
Float Housing: High Impact PVC, 3.25" diameter x 4.55" length
Max Temperature: 140 degrees F.
Switch Configuration: Single Pole, Single Throw
Alarm Systems
Control Panels
PO Box 827
Hawley, MN 56549
Externally Weighted Models
Float Switches
Leak Detection Systems
(218) 483-3034
Fax (218) 483-3034
UL Listed. Suitable for use in water and sew-
age. End user to provide overcurrent protection
rated at 240 VAC Minimum, 15 A maximum.
Figure 2
Unimax
Control
Float
Activation Level
Big Switch
Pump Float
Alderon Industries, LLC
P.O. Box 827
Hawley, MN 56549
Page 1 of 1
www.alderonind.com
P/N 10059 Rev A
4/19/00
Phone: 218.483.3034
Fax: 218.483.3036