Alderon Industries Power Post VA-02 Manuale di funzionamento, manutenzione e installazione

Sfoglia online o scarica il pdf Manuale di funzionamento, manutenzione e installazione per Sistema di sicurezza Alderon Industries Power Post VA-02. Alderon Industries Power Post VA-02 4. 1-zone septic alarm

Alderon Industries Power Post VA-02 Manuale di funzionamento, manutenzione e installazione
Power Post
1-Zone Septic Alarm
Standard, Model: VA-02 | Rated Type 1 (Indoor), Alarm Panel
Operation, Maintenance, and Installation Manual
Safety Guidelines
1. DISCONNECT ALL ELECTRICAL SERVICE BEFORE WORKING ON OR HANDLING THE PRODUCT.
2. DO NOT USE WITH FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GASOLINE, FUEL OIL, KEROSENE, ETC.
DO NOT USE IN EXPLOSIVE ATMOSPHERES.
3. ALARM PANEL MUST BE MOUNTED INDOORS. FOR OUTDOOR APPLICATIONS, CONSULT FACTORY.
Specifications
Primary Power
120VAC, 50/60 Hz
Circuit Board Primary Power
11.1VDC, 500mA maximum
Circuit Board Secondary Power
9VDC, standard 9VDC battery
(battery backup; not included)
Watts
1.4 Watts
Field Connection Sensor
9-10VDC, 200mA minimum
(signaling device)
Description of Operation
The Power Post™ 1-Zone Septic Alarm is an indoor rated alarm panel, powered by a standard 120VAC wall outlet. The
green power LED will illuminate (solid) when powered. The Power Post™ septic alarm panel can only be used with and
connected to an Alderon™ Power Post™ pump connection or monitoring system for remote alarm notification.
The alarm panel is equipped with audible and visual alarm indication, activated by the Power Post™ system auxiliary
contacts or alarm sensor(s) wired to the Power Post™ septic alarm panel. Installing a 9VDC battery (not included)
provides battery backup during power outages. Use the auxiliary contacts on the Power Post™ septic alarm panel to
connect to building automation systems (BAS) and phone dialers. Multiple sensors (signaling device) can be connected
for expanded monitoring.
An alarm condition occurs when the Power Post™ system auxiliary contacts or alarm sensor(s) are activated, during which
the Power Post™ septic alarm panel red alarm LED will illuminate (solid), buzzer will annunciate (solid), and the auxiliary
contacts will activate. The alarm condition of the Power Post™ septic alarm panel will stay on until the Power Post™ system
auxiliary contacts or alarm sensor(s) are deactivated. If the alarm silence pushbutton is pressed during an alarm condition,
it will silence the buzzer while the alarm LED remains on. The silence condition will reset when the Power Post™ system
auxiliary contacts or alarm sensor(s) are deactivated and the Power Post™ septic alarm panel will auto reset for the next
alarm cycle.
QSG00314_Rev02_Power Post 1-Zone Indoor Septic Alarm Standard VA-02 | November 22, 2021 1:15 PM
Alderon Industries, LLC - Leading Edge Control Products | 218.483.3034 | [email protected] | [email protected] | alderonind.com
Introduction
Before proceeding with the installation or operation of the product, make sure to read all
instructions thoroughly, as well as complying with all Federal, State and Local Codes,
Regulations and Practices. The product must be installed by qualified personnel familiar
with all applicable local electrical and mechanical codes. Refer to the National Electrical
Code (NFPA 70). Failure to properly install and test this product can result in personal injury
or equipment malfunction.
Auxiliary Contacts
24VDC, 500mA maximum
Normally Open; Single Pole, Single Throw
Auxiliary Alarm Power
8-10.2VDC, 150mA maximum
LEDs
Green (power) and Red (alarm)
Buzzer
85 dB @ 10-feet
Wall-Mounted Power Supply
120VAC, 50/60 Hz (input)
11.1VDC, 500mA maximum (output)
(6-foot cord)
Enclosure
Thermoplastic
5 x 4 x 1.3 (inches)
Type 1, Indoor
Removable cover
Certifications
CSA (US and Canada)
Three-Year Limited Warranty
Installation Instructions | Page 1